Lexicon / Glossary

Current and voltage generation: Techniques and challenges in precise current and voltage generation for test purposes

Basics of precise current and voltage generation

The exact generation of electrical signals forms the foundation of modern measurement technology. Precise current and voltage sources must generate defined values with minimal deviations and effectively suppress interference. The electrical current as the movement of charge carriers and the voltage as the driving force of this movement are in a relationship defined by Ohm’s law.

Signal generation is particularly challenging in the micro and nano range, where even the smallest disturbances have significant effects. The quality of a voltage or current source is measured by parameters such as accuracy, stability, noise and load dependency. The reproducibility of the generated values also plays a decisive role, especially if measurements are to be compared over longer periods of time.

Traceability to international standards ensures comparability of measurement results across institutions and national borders. Metrological traceability requires a seamless calibration path to primary standards. Precisely defined reference values for current and voltage therefore form the basis for every precise electrical measurement.

Requirements for modern test devices

Modern test equipment must meet a constantly growing range of requirements. The semiconductor industry requires current sources with nanometer resolution and high dynamics for the characterization of highly integrated circuits. Communication technology applications, on the other hand, require signal sources with a precisely defined bandwidth and minimal distortion for the simulation of real transmission conditions.

In the energy sector, the need for precise reference sources for the calibration of intelligent measuring systems is increasing. These must be able to deliver high performance with minimal harmonic content. In addition, remote controllability and network integration are increasingly required to enable automated test sequences and increase efficiency.

The miniaturization of electronic components poses additional challenges, as ever smaller structures also react more sensitively to overloads. Test devices must therefore implement precise current limits and fast switch-off mechanisms to protect valuable test specimens. At the same time, the requirements for measured value resolution are increasing, while the permissible calibration error is continuously decreasing.

Differences between voltage and current sources

Voltage sources and current sources differ fundamentally in their behavior under load. An ideal voltage source always supplies the same voltage regardless of the connected load. Its internal resistance is theoretically close to zero, in practice it is in the milliohm range. This enables a stable voltage supply even if the current consumption of the connected load fluctuates greatly.

In contrast, an ideal current source keeps the current flowing through the load constant, regardless of the load resistance. Its internal resistance tends towards infinity, which means that the output voltage increases proportionally to the load resistance. This makes current sources particularly suitable for applications such as impedance measurement or the characterization of semiconductor components.

The choice between voltage and current source depends largely on the application in question. Voltage sources are preferred for component tests where a defined operating voltage is required. If, on the other hand, a constant current is required, for example when measuring contact resistances or testing current limiting circuits, current sources are the method of choice. Programmable sources that combine both operating modes are also becoming increasingly important.

Technologies for precise voltage generation

Precise voltage generation is based on sophisticated circuit concepts and state-of-the-art components. At the heart of every high-quality voltage source is a stable reference that provides a constant value regardless of external influences. This base voltage is then scaled and processed to the desired value using analog or digital circuit technology.

Feedback systems play a central role in voltage stabilization. They continuously compare the actual value with the target value and correct deviations. The bandwidth of these control loops largely determines how quickly the source can react to load changes. High-quality laboratory power supplies achieve stabilization times in the microsecond range with voltage fluctuations of less than one millivolt.

Minimizing the effects of noise requires special attention. This includes careful layout design, shielding measures and filter structures that suppress unwanted frequency components. The use of high-quality components with low inherent noise and a low temperature coefficient makes a decisive contribution to long-term stability. Modern voltage sources for test purposes combine all these aspects to ensure maximum precision.

Reference voltage sources

Reference voltage sources are at the heart of any precise voltage generation. Bandgap references utilize the almost temperature-independent bandgap voltage of semiconductors and achieve typical stabilities of 10 ppm/°C. They can be found in almost every precise measurement circuit and offer a good compromise between accuracy and cost.

Zener diode references use the defined breakdown of special diodes in the blocking region. Buried Zener structures in particular achieve excellent long-term stability. Drift coefficients of less than 2 ppm/year can be achieved through temperature compensation and ageing pre-treatment. These references are mainly used in high-quality calibrators where absolute accuracy is required.

Quantum standards serve as a reference for the highest metrological requirements. The Josephson voltage standard uses quantum mechanical effects in superconducting tunnel contacts and provides a voltage that is directly traceable to natural constants. With a relative uncertainty of less than 10^-9, it represents the pinnacle of technical possibilities and is used in national metrology institutes. For practical applications, these primary standards are replaced by transfer standards with Zener references that are regularly calibrated.

Digital-to-analog converter (DAC)

Digital-to-analog converters form the interface between digital signal processing and analog voltage generation. Modern DACs achieve resolutions of 18 to 24 bits, which theoretically enables voltage division into more than 16 million levels. For precision applications, R-2R networks or weighted capacitors are usually used, the accuracy of which is optimized by laser adjustment or digital calibration.

In addition to the pure resolution, the linearity of the converter is also decisive for the signal quality. The integral non-linearity (INL) describes the maximum deviation from the ideal transmission behavior and should be less than half an LSB for precision applications. Modern high-performance DACs use segmentation and dynamic element balancing to achieve impressive INL values at a high output rate.

To generate dynamic test signals, DACs also require a precise clock supply and effective reconstruction filters. Jitter in the clock leads to phase noise in the output signal, while inadequate filtering allows interference frequencies to pass through. Advanced DAC systems therefore integrate highly stable oscillators and optimized filter structures directly on the chip. This enables them to generate high-precision voltage signals with a defined frequency response for demanding test scenarios.

Linear amplifiers and control loops

Linear amplifiers form the link between reference voltages and powerful output circuits. For maximum precision, chopper-stabilized operational amplifiers are used that achieve offset voltages in the nanovolt range. These minimize drift effects by continuously switching the signal paths and then filtering out unwanted components. The gain error of modern precision amplifiers is typically less than 0.001%.

The control loop technology enables active compensation of interference. The output voltage is continuously measured and compared with the target value. The control loop corrects deviations by adjusting the control variables accordingly. The challenge lies in the optimal coordination of control speed and stability, especially with capacitive loads that can tend to oscillate.

Multi-stage control concepts combine fast feedforward control with precise tracking. The pre-control reacts immediately to load changes, while the downstream precision control eliminates any remaining deviations. This architecture combines fast response with maximum accuracy. For particularly low-noise applications, special filter structures are also used to suppress unwanted frequency components without impairing the control dynamics.

Direct digital synthesis for dynamic signals

Direct digital synthesis (DDS) is revolutionizing the generation of dynamic current and voltage signals. In this process, digital signal forms are stored in a memory and read out at a high clock rate. A downstream DAC converts the digital values into analog signals. The frequency can be set with extremely high resolution by changing the readout step size – modern DDS systems achieve frequency resolutions in the microhertz range.

A particular advantage of DDS technology is its flexibility in signal generation. Almost any waveform can be realized by appropriate programming. This enables the precise simulation of real load profiles or specific test signals with defined harmonic components. For current control, the DDS output signal is transformed into the desired current range by a downstream voltage-current converter.

The phase purity of the generated signals depends largely on the quality of the system clock. High-quality DDS generators therefore use temperature-stabilized quartz oscillators or atomic frequency standards as a reference. The achievable signal quality is characterized by parameters such as signal-to-noise ratio (SNR) and Spurious-Free Dynamic Range (SFDR). Advanced DDS systems achieve SFDR values of over 90 dB, which qualifies them for demanding test applications.

Calibration procedures for current sources

The calibration of current sources requires special procedures that differ from those for voltage sources. The basic method is to measure the current generated by a calibrated ammeter or via the voltage drop across a precision resistor. The latter approach dominates in practice, as reference resistors with uncertainties of less than 1 ppm are available and the voltage measurement can be traced back to established voltage standards.

Different resistance values are used for different current ranges. While high-ohm resistors with low self-heating are used in the microampere range, currents in the ampere range require low-ohm precision shunts with effective heat dissipation. The four-point measurement technology eliminates the influence of contact and lead resistances and thus enables maximum measurement accuracy.

Automated calibration systems enable efficient characterization over the entire operating range. They record systematic deviations and store correction factors in digital tables. This calibration data is evaluated during operation by interpolation algorithms and used to correct the initial values. Regular recalibration and comparative measurements with reference standards ensure traceability to international standards and guarantee long-term measurement accuracy.

Challenges in precision generation

The precision generation of electrical signals presents developers with a variety of challenges. In addition to the basic circuitry aspects, numerous external influences that can affect signal quality must be taken into account. These range from thermal effects and electromagnetic interference to ageing processes of the components used.

Environmental influences that change over time and thus cause drift phenomena are particularly critical. Ensuring constant signal quality over long periods of time requires sophisticated compensation strategies. Both analog and digital technologies are used to continuously record and correct deviations.

The miniaturization of electronic systems further exacerbates this problem. The smaller the structures become, the more sensitive they are to interference. At the same time, the demands on signal quality are increasing due to ever more precise measurement methods and more sensitive test specimens. Overcoming these opposing trends requires innovative solutions at circuit, component and system level.

Thermal effects and temperature stabilization

Thermal effects are one of the dominant influencing factors in precision sources. Every electronic component has a temperature-dependent characteristic curve that affects the overall behavior of the system. Reference elements are particularly critical, as even the smallest temperature changes can lead to measurable deviations. Typical temperature coefficients of high-quality reference sources are 1-5 ppm/°C.

Active temperature stabilization using Peltier elements offers an effective solution to this problem. These keep critical components at a constant operating temperature, regardless of the environment. In precision laboratories, air-conditioned housings are also used to ensure a constant temperature with deviations of less than 0.1°C. For portable devices, on the other hand, digital compensation methods with integrated temperature sensors are often used.

Self-heating due to power loss poses a further challenge. Power components can generate local temperature gradients that affect sensitive components. Sophisticated thermal design with effective heat dissipation and strategic component placement minimizes these effects. In circuit development, transient thermal processes must also be taken into account, which occur after switch-on processes or load changes and only reach a stable state after a certain settling time.

Noise and EMC influences

Noise is a fundamental limit for the achievable signal precision. Various noise sources overlap and impair the signal quality. Thermal noise is caused by statistical charge carrier movements and can only be reduced by cooling. 1/f noise dominates at low frequencies and makes it particularly difficult to generate slowly changing signals. Special low-noise components and circuit technologies are therefore required for voltage sources in the microvolt range and current sources in the nanoampere range.

Electromagnetic interference from the environment can significantly impair precise signals. Digital systems, switching power supplies and communication devices generate high-frequency interference fields that penetrate sensitive circuit components through coupling. Multi-layer shielding made of special materials, galvanic isolation of critical circuit parts and careful filtering of the supply voltages reduce these influences. Special attention must also be paid to the PCB design with well thought-out ground routing and signal path separation.

EMC-compliant design includes preventive measures as early as the development phase. Differential signal routing improves interference immunity by suppressing common mode interference. Optical or magnetic transmission paths decouple sensitive circuit components from interfering environments. With field test devices, there is the additional challenge of ensuring precise measurements even under unfavorable conditions. Robust input filters and adaptive amplification systems help to meet this requirement.

Long-term stability and ageing effects

The long-term stability of precise sources is significantly influenced by ageing processes of electronic components. These manifest themselves as slow but continuous changes in electrical parameters. Semiconductor elements, in which diffusion processes and interface changes take place, are particularly affected. High-quality reference components therefore undergo an artificial ageing process before use, which reduces the initial strong drift.

The quantitative prediction of ageing effects is difficult, as numerous factors interact. Empirical models based on long-term measurements allow a rough estimate of the expected drift. Typical values are 2-5 ppm per year for precision references after the running-in phase. To ensure maximum accuracy, metrological applications carry out regular recalibrations and document the results in ageing curves.

Compensation strategies for ageing effects include both hardware and software approaches. At hardware level, redundant systems with averaging are used to compensate for statistical fluctuations. On the software side, adaptive algorithms are implemented that calculate drift models based on historical calibration data and make appropriate corrections. Predictive models, which take into account operating parameters such as temperature cycles and load profiles in addition to age, are particularly effective and thus enable a more accurate prediction of the expected parameter drift.

Applications of precise current and voltage sources

Precise current and voltage sources are used in numerous fields of application where exact electrical signals are essential. The specific requirements vary considerably between industries. While the semiconductor industry primarily requires low voltages and currents with maximum precision, applications in energy technology often require higher outputs with moderate accuracy.

Calibration laboratories place particularly high demands on the metrological traceability and long-term stability of the sources used. Multiple redundant systems are often used here, which are monitored by regular comparison measurements. The continuous documentation of all deviations guarantees the traceability of measurement results over long periods of time.

Research facilities, on the other hand, often require flexible sources that can be adapted to a wide variety of experimental setups. Programmable systems with extensive interfaces enable integration into complex experimental set-ups and automated measurement sequences. The requirements range from nanoampere currents for quantum physics experiments to high-precision high voltages for material science investigations.