Testing of AC charging stations in compliance with calibration law up to 120 A and 320 V
The MTS310e source and test system uses the Reference Meter EPZ303, which is capable of measuring AC currents of up to 120 A. The new digital measuring system of the STM4000 series serves as an “error calculator”, i.e. it determines the measurement deviation of the DUT. The system is extendable for additional test positions. A necessary DUT connection can be supplied on request.
End-of-line test – MTS310e
This test and source system can be used by manufacturers for charging stations for electric vehicles for stationary testing of AC charging stations, for example, at the end of the production process for quality control.
Components of the MTS310e
Mechanical part
Safety components
Further optional components
- DTS100, Mobile computer and scanner
- DUT connection on request